ID.4 2021 ➤, ID.3 2020 ➤
Electric rear-wheel drive EIP220 and all-wheel drive EIA200, EIP220 - Edition 11.2021
Stage Bolts
Tightening torque/angle specification
-1.1- to -4.4- 4.5 Nm
-2- to -6- 8 Nm
1.
2.
5.11
Assembly overview – high-voltage bat‐
tery, connecting element, 82 kWh
5.11.1
Exploded view - high-voltage battery, connector strip
1 - Connector strip
❑ ⇒ Rep. gr. 93; Remov‐
ing and installing con‐
necting element, 48,
55 kWh
2 - Bolt
❑ 5x
❑ M6 x 20
3 - Bolt
❑ 16x
❑ Renew after removing
❑ Tightening torque and
sequence ⇒ page 176
❑ M5 x 25
Tightening torque and sequence
176
Rep. gr.93 - Electric drive systems
ID.4 2021 ➤, ID.3 2020 ➤
Electric rear-wheel drive EIP220 and all-wheel drive EIA200, EIP220 - Edition 11.2021
Stage Bolts
Tightening torque/angle specification
1.
2.
-1.1- to -4.4- 4.5 Nm
-2- to -6-
8 Nm
5.12
Removing battery module
Special tools and workshop equipment required
♦ High-voltage tool set -VAS 6762-
♦ accidental contact protection -T10608-
♦ accidental contact protection insert -T10628-
♦ adapter -10-222A/14-
♦ high-voltage tool set -VAS 6883A-
♦ hook -10-222A/10-
♦ lifting aid -T10619-
♦ lifting tackle -3033-
♦ removal wedge set -VAS 895 015-
♦ shackle -10-222A/12-
♦ support bracket -10-222B-
♦ workshop hoist -VAS 6100-
DANGER
Danger to life from high voltage.
Electric shocks or arcs may lead to serious injuries or death.
– Suitable personal protective equipment (PPE) must be
worn for the subsequent work steps.
– The subsequent work steps must be supervised by an
additional specialist with appropriate qualification.
– Outside the hazard area, the additional authorised special‐
ist can support the HVE as required within the scope of his
or her qualification.
Put on the required protective equipment for the subsequent
work steps:
5. High-voltage battery components
177

2024 VW ID.4 Owner's Manual