Table of Contents > Electric drive systems > High-voltage battery components > Removing and installing connecting element, 48, 55 kWh

VW ID.4 Electric rear-wheel and all-wheel drive ➜ Removing and installing connecting element, 48, 55 kWh

ID.4 2021 ➤, ID.3 2020 ➤  
Electric rear-wheel drive EIP220 and all-wheel drive EIA200, EIP220 - Edition 11.2021  
5.15  
Removing and installing connecting el‐  
ement, 48, 55 kWh  
5.15.1  
Removing and installing connecting el‐  
ement  
Special tools and workshop equipment required  
♦ High-voltage tool set -VAS 6762-  
♦ Torque wrench -VAS 6883/1A-  
♦ accidental contact protection -T10608-  
♦ accidental contact protection insert -T10628-  
DANGER  
Danger to life from high voltage.  
Electric shocks or arcs may lead to serious injuries or death.  
– Suitable personal protective equipment (PPE) must be  
worn for the subsequent work steps.  
– The subsequent work steps must be supervised by an  
additional specialist with appropriate qualification.  
– Outside the hazard area, the additional authorised special‐  
ist can support the HVE as required within the scope of his  
or her qualification.  
Put on the required protective equipment for the subsequent  
work steps:  
♦ Arc flash resistant clothing (at least APC 2, at least 318 kJ)  
♦ Helmet with arc flash resistant visor (at least APC 2, at least  
318 kJ)  
♦ Arc flash resistant gloves with nitrile glove liners (at least  
APC 2, at least 318 kJ), insulating up to at least 500 V  
♦ Safety shoes with ESD protection  
The switching unit for high-voltage battery, negative terminal  
-SX7- will henceforth be referred to as “switching unit, negative  
terminal”.  
Removing  
– ⇒ Rep. gr. 93; Opening high-voltage battery 1 [AX2].  
– ⇒ Rep. gr. 93; Opening electrical circuit, 48, 55 kWh.  
– Fit accidental contact protection insert -T10628- onto battery  
module 1 -J991-.  
186  
Rep. gr.93 - Electric drive systems  
ID.4 2021 ➤, ID.3 2020 ➤  
Electric rear-wheel drive EIP220 and all-wheel drive EIA200, EIP220 - Edition 11.2021  
– Unscrew bolts -2- from high-voltage connector -1- on switch‐  
ing unit, negative terminal -3- and battery module 1 -J991-.  
– Remove high-voltage connector -1-.  
– Fit accidental contact protection -T10608- onto exposed  
high-voltage connection on battery module 1 -J991-.  
– Detach cap for switching unit, negative terminal -3-.  
– Unscrew bolts -2-.  
– Unscrew bolts -3-.  
– Remove connecting element -1-.  
Installing  
Install in reverse order of removal, observing the following:  
– Check seal for damage.  
– Keep sealing surface free of dust and grease. Clean with  
cleaning solution ⇒ Electronic parts catalogue (ETKA).  
– Apply sealant all around on outer side of connecting ele‐  
ment, next to existing seal. Sealant ⇒ Electronic parts cata‐  
logue (ETKA).  
– When installing, pay attention to equal tolerance between  
connecting element and lower part of battery housing. Seal  
must come fully into contact with lower part of battery hous‐  
ing.  
– After installation of a high-voltage connector, measurements  
must be performed to make sure there is no risk of a short-  
circuit to the lower part of battery housing.  
– Have all torque settings checked by a 2nd mechanic.  
Tightening torques  
♦ ⇒ Rep. gr. 93; Assembly overview – switching unit for high-  
voltage battery, 48, 55, 62 kWh  
♦ ⇒ Rep. gr. 93; Assembly overview – high-voltage battery,  
connecting element, 48, 55, 62 kWh  
5. High-voltage battery components  
187  
ID.4 2021 ➤, ID.3 2020 ➤  
Electric rear-wheel drive EIP220 and all-wheel drive EIA200, EIP220 - Edition 11.2021  
5.16  
Removing and installing connecting el‐  
ement, 62 kWh  
5.16.1  
Removing and installing connecting el‐  
ement  
Special tools and workshop equipment required  
♦ High-voltage tool set -VAS 6762-  
♦ Torque wrench -VAS 6883/1A-  
♦ accidental contact protection -T10608-  
♦ accidental contact protection insert -T10628-  
DANGER  
Danger to life from high voltage.  
Electric shocks or arcs may lead to serious injuries or death.  
– Suitable personal protective equipment (PPE) must be  
worn for the subsequent work steps.  
– The subsequent work steps must be supervised by an  
additional specialist with appropriate qualification.  
– Outside the hazard area, the additional authorised special‐  
ist can support the HVE as required within the scope of his  
or her qualification.  
Put on the required protective equipment for the subsequent  
work steps:  
♦ Arc flash resistant clothing (at least APC 2, at least 318 kJ)  
♦ Helmet with arc flash resistant visor (at least APC 2, at least  
318 kJ)  
♦ Arc flash resistant gloves with nitrile glove liners (at least  
APC 2, at least 318 kJ), insulating up to at least 500 V  
♦ Safety shoes with ESD protection  
The switching unit for high-voltage battery, negative terminal  
-SX7- will henceforth be referred to as “switching unit, negative  
terminal”.  
Removing  
– ⇒ Rep. gr. 93; Opening high-voltage battery 1 [AX2].  
– ⇒ Rep. gr. 93; Opening electrical circuit, 48, 55 kWh.  
– Fit accidental contact protection insert -T10628- onto battery  
module 1 -J991-.  
188  
Rep. gr.93 - Electric drive systems  

Need help?