15 - Refrigerant shut-off valve 3 -N641-  
❑ ⇒ Rep. gr. 87; Removing and installing refrigerant shut-off valve 3 N641  
16 - Dryer with internal heat exchanger  
❑ ⇒ Rep. gr. 87; Removing and installing dryer  
17 - Refrigerant pressure and temperature sender 5 -G829-  
❑ ⇒ Rep. gr. 87; Removing and installing refrigerant pressure and temperature sender 5 G829  
18 - Air conditioner compressor -VX81-  
❑ ⇒ Rep. gr. 87; Removing and installing air conditioner compressor VX81  
19 - Refrigerant pressure and temperature sender -G395-  
❑ ⇒ Rep. gr. 87; Removing and installing refrigerant pressure and temperature sender G395  
20 - Refrigerant shut-off valve 2 -N640-  
❑ ⇒ Rep. gr. 87; Removing and installing refrigerant shut-off valve 2 N640  
21 - Refrigerant shut-off valve 5 -N643-  
❑ ⇒ Rep. gr. 87; Removing and installing refrigerant shut-off valve 5 N643  
22 - Refrigerant pressure and temperature sender 3 -G827-  
❑ ⇒ Rep. gr. 87; Removing and installing refrigerant pressure and temperature sender 3 G827  
3.3  
Assembly overview – refrigerant lines,  
R1234yf  
3.3.1  
Exploded view - refrigerant lines  
3. Refrigerant circuit  
19  
ID.4 2021 ➤  
Heating, air conditioning system - Edition 09.2021  
1 - Bolt  
❑ Applies for all connec‐  
tions in illustration  
❑ 8 Nm  
2 - Seal  
❑ Applies for all connec‐  
tions in illustration  
❑ Renew after removing  
3 - Refrigerant line  
❑ ⇒ Rep. gr. 87; Remov‐  
ing and installing re‐  
frigerant line from con‐  
denser to expansion  
valve  
4 - Pressure sender for refrig‐  
erant circuit -G805-  
❑ ⇒ Rep. gr. 87; Remov‐  
ing and installing pres‐  
sure sender for refriger‐  
ant circuit G805  
❑ 8 Nm  
5 - Seal  
❑ Renew after removing  
6 - Valve core  
❑ 1.5 Nm  
7 - Refrigerant shut-off valve  
for heater and air conditioning  
unit -N541-  
❑ ⇒ Rep. gr. 87; Remov‐  
ing and installing refrig‐  
erant shut-off valve for  
heater and air condi‐  
tioning unit N541  
8 - Union nut  
❑ 16.5 Nm  
9 - Evacuating and charging valve (high-pressure side)  
❑ ⇒ Rep. gr. 87; Removing and installing evacuating and charging valve (low-pressure and high-pres‐  
sure sides)  
❑ 1.5 Nm  
10 - Valve cap (high pressure)  
❑ 1 Nm  
11 - Refrigerant line  
❑ ⇒ Rep. gr. 87; Removing and installing refrigerant line from heat exchanger for high-voltage battery to  
high-pressure line  
12 - Bracket  
13 - Refrigerant line  
❑ ⇒ Rep. gr. 87; Removing and installing refrigerant line from air conditioner compressor VX81 to  
expansion valve  
14 - Expansion valve  
❑ ⇒ Rep. gr. 87; Exploded view - evaporator housing  
❑ ⇒ Rep. gr. 87; Removing and installing expansion valve  
20  
Rep. gr.87 - Air conditioning system  
ID.4 2021 ➤  
Heating, air conditioning system - Edition 09.2021  
15 - Valve core  
❑ 2 Nm  
16 - Seal  
❑ Renew after removing  
17 - Refrigerant pressure and temperature sender -G395-  
❑ ⇒ Rep. gr. 87; Removing and installing refrigerant pressure and temperature sender G395  
❑ 10 Nm  
18 - Valve cap (low pressure)  
❑ 1 Nm  
19 - Evacuating and charging valve (low-pressure side)  
❑ ⇒ Rep. gr. 87; Removing and installing evacuating and charging valve (low-pressure and high-pres‐  
sure sides)  
❑ 1.5 Nm  
20 - Refrigerant line  
❑ ⇒ Rep. gr. 87; Removing and installing refrigerant line from heat exchanger for high-voltage battery to  
low-pressure line  
21 - Bolt  
❑ 2x  
❑ 20 Nm  
22 - Air conditioner compressor -VX81-  
❑ ⇒ Rep. gr. 87; Exploded view - air conditioner compressor  
❑ ⇒ Rep. gr. 87; Removing and installing air conditioner compressor VX81  
23 - Refrigerant line  
❑ ⇒ Rep. gr. 87; Removing and installing refrigerant line from condenser to air conditioner compressor  
VX81  
24 - Condenser  
❑ ⇒ Rep. gr. 87; Exploded view - condenser  
❑ ⇒ Rep. gr. 87; Removing and installing condenser  
25 - High-voltage battery heat exchanger  
❑ ⇒ Rep. gr. 87; Exploded view - heat exchanger for high-voltage battery  
❑ ⇒ Rep. gr. 87; Removing and installing heat exchanger for high-voltage battery  
3.4  
Assembly overview – refrigerant lines,  
R744  
3.4.1  
Exploded view - refrigerant lines  
3. Refrigerant circuit  
21  