Table of Contents > 2 Overview of fitting locations – air conditioning system > 2.1 Overview of fitting locations – components not located in passenger compartment, with heat pump

VW ID.4 Heating & Air Conditioning System ➜ 2.1 Overview of fitting locations – components not located in passenger compartment, with heat pump

ID.4 2021 ➤  
Heating, air conditioning system - Edition 09.2021  
2
Overview of fitting locations – air  
conditioning system  
2.1  
Overview of fitting locations – compo‐  
nents not located in passenger com‐  
partment, with heat pump  
2.1.1  
Overview of fitting locations - components not located in passenger com‐  
partment  
2. Overview of fitting locations – air conditioning system  
7
ID.4 2021 ➤  
Heating, air conditioning system - Edition 09.2021  
1 - Gas cooler  
❑ ⇒ Rep. gr. 87; Remov‐  
ing and installing gas  
cooler  
2 - Refrigerant pressure and  
temperature sender 5 -G829-  
❑ ⇒ Rep. gr. 87; Remov‐  
ing and installing re‐  
frigerant pressure and  
temperature sender 5  
[G829]  
3 - Dryer  
❑ ⇒ Rep. gr. 87; Remov‐  
ing and installing dryer  
4 - Heat exchanger for high-  
voltage battery  
❑ ⇒ Rep. gr. 87; Remov‐  
ing and installing heat  
exchanger for high-volt‐  
age battery  
5 - Refrigerant pressure and  
temperature sender 2 -G826-  
❑ ⇒ Rep. gr. 87; Remov‐  
ing and installing re‐  
frigerant pressure and  
temperature sender 2  
[G826]  
6 - Refrigerant shut-off  
valve 4 -N642-  
❑ ⇒ Rep. gr. 87; Assem‐  
bly overview – valve  
unit of heat pump  
❑ ⇒ Rep. gr. 87; Remov‐  
ing and installing refrig‐  
erant shut-off valve 4  
[N642]  
7 - Refrigerant shut-off valve 5 -N643-  
❑ ⇒ Rep. gr. 87; Assembly overview – valve unit of heat pump  
❑ ⇒ Rep. gr. 87; Removing and installing refrigerant shut-off valve 5 [N643]  
8 - Refrigerant expansion valve 2 -N637-  
❑ ⇒ Rep. gr. 87; Assembly overview – valve unit of heat pump  
❑ ⇒ Rep. gr. 87; Removing and installing refrigerant expansion valve 2 [N637]  
9 - Refrigerant expansion valve 3 -N638-  
❑ ⇒ Rep. gr. 87; Assembly overview – valve unit of heat pump  
❑ ⇒ Rep. gr. 87; Removing and installing refrigerant expansion valve 3 [N638]  
10 - Refrigerant shut-off valve 1 -N696-  
❑ ⇒ Rep. gr. 87; Assembly overview – valve unit of heat pump  
❑ ⇒ Rep. gr. 87; Removing and installing refrigerant shut-off valve 1 [N696]  
11 - Refrigerant expansion valve 1 -N636-  
❑ ⇒ Rep. gr. 87; Assembly overview – valve unit of heat pump  
❑ ⇒ Rep. gr. 87; Removing and installing refrigerant expansion valve 1 [N636]  
12 - Refrigerant pressure and temperature sender 4 -G828-  
❑ ⇒ Rep. gr. 87; Removing and installing refrigerant pressure and temperature sender 4 [G828]  
8
Rep. gr.87 - Air conditioning system  
ID.4 2021 ➤  
Heating, air conditioning system - Edition 09.2021  
13 - Evacuating and charging valve  
❑ High-pressure side  
❑ ⇒ Rep. gr. 87; Removing and installing evacuating and charging valves on low and high-pressure side  
14 - Evacuating and charging valve  
❑ Low-pressure side  
❑ ⇒ Rep. gr. 87; Removing and installing evacuating and charging valves on low and high-pressure side  
15 - Air intake box of heater and air conditioning unit  
❑ ⇒ Rep. gr. 87; Assembly overview – air intake unit of heater and air conditioning unit  
❑ ⇒ Rep. gr. 87; Removing and installing air intake unit of heater and air conditioning unit  
16 - External air quality and air humidity sensor -G935-  
❑ ⇒ Rep. gr. 87; Removing and installing external air quality and humidity sensor [G935]  
17 - Fresh air intake  
❑ ⇒ Rep. gr. 87; Removing and installing fresh air intake  
18 - Fresh air blower control unit -J126-  
❑ ⇒ Rep. gr. 87; Assembly overview – air intake unit of heater and air conditioning unit  
❑ ⇒ Rep. gr. 87; Removing and installing fresh air blower control unit [J126]  
19 - Control motor for fresh air and air recirculation flap -VX96-  
❑ ⇒ Rep. gr. 87; Assembly overview – air intake unit of heater and air conditioning unit  
❑ ⇒ Rep. gr. 87; Removing and installing control motor for fresh air and air recirculation flap [VX96]  
20 - Refrigerant shut-off valve 3 -N641-  
❑ ⇒ Rep. gr. 87; Assembly overview – valve unit of heat pump  
❑ ⇒ Rep. gr. 87; Removing and installing refrigerant shut-off valve 3 [N641]  
21 - Refrigerant shut-off valve 2 -N640-  
❑ ⇒ Rep. gr. 87; Assembly overview – valve unit of heat pump  
❑ ⇒ Rep. gr. 87; Removing and installing refrigerant shut-off valve 2 [N640]  
22 - PTC heater element 3 -Z132-  
❑ ⇒ Rep. gr. 87; Assembly overview – high-voltage heater (PTC)  
❑ ⇒ Rep. gr. 87; Removing and installing PTC heater element 3 [Z132]  
23 - Refrigerant pressure and temperature sender -G395-  
❑ ⇒ Rep. gr. 87; Removing and installing refrigerant pressure and temperature sender [G395]  
24 - Air conditioner compressor -VX81-  
❑ With control unit for air conditioner compressor -J842-  
❑ With electrical air conditioner compressor -V470-  
❑ ⇒ Rep. gr. 87; Assembly overview – air conditioner compressor  
❑ ⇒ Rep. gr. 87; Removing and installing air conditioner compressor [VX81]  
25 - Refrigerant pressure and temperature sender 3 -G827-  
❑ ⇒ Rep. gr. 87; Removing and installing refrigerant pressure and temperature sender 3 [G827]  
26 - Ambient temperature sensor -G17-  
❑ ⇒ Rep. gr. 87; Removing and installing ambient temperature sensor [G17]  
2. Overview of fitting locations – air conditioning system  
9

Need help?

If after viewing the owner's manual or service manual you still have some unresolved questions about the car VW ID.4 you can write to us using the link below, describing your problem in detail, we try to answer all questions.


Ask your question on the page - Support!