Table of Contents > 3 Refrigerant circuit > 3.17 Removing and installing evacuating and charging valves on low and high-pressure side, R744

VW ID.4 Heating & Air Conditioning System ➜ 3.17 Removing and installing evacuating and charging valves on low and high-pressure side, R744

ID.4 2021 ➤  
Heating, air conditioning system - Edition 09.2021  
CAUTION  
Risk of frostbite from escaping pressurised refrigerant  
Risk of frostbite on skin and other parts of the body  
– Put on protective gloves.  
– Put on safety goggles.  
– Extract/drain refrigerant and then immediately open up re‐  
frigerant circuit.  
– Extract/drain refrigerant again if more than 10 minutes  
have passed since initial extraction and refrigerant circuit  
has not been opened up. Renewed evaporation has cre‐  
ated pressure in the refrigerant circuit.  
– Remove valve core -2- using socket -T10364/4A-.  
Installing  
Installation is carried out in reverse order; note the following:  
– ⇒ Air conditioners with refrigerant R1234yf - General infor‐  
mation; Rep. gr. 87; Working with the air conditioner service  
station; Charging refrigerant circuit  
Tightening torques  
♦ ⇒ Rep. gr. 87; Exploded view - refrigerant lines  
3.17  
Removing and installing evacuating  
and charging valves on low and high-  
pressure side, R744  
3.17.1  
Removing and installing evacuating  
and charging valve (low-pressure and  
high-pressure sides)  
Special tools and workshop equipment required  
♦ engine bung set -VAS 6122-  
♦ socket -T10364/5-  
Removing  
Seal off open pipes/lines and connections immediately with  
clean plugs from engine bung set -VAS 6122-.  
– Perform function “Opening electrically actuated valves in re‐  
frigerant circuit for extracting, evacuating and charging” with  
⇒ Vehicle diagnostic tester ⇒ Rep. gr. 00; Starting diagnosis.  
– ⇒ Air conditioners with refrigerant R744 - General informa‐  
tion; Rep. gr. 87; Working with the air conditioner service  
station; Discharging refrigerant circuit.  
– Detach protective cap -3-.  
3. Refrigerant circuit  
37  
ID.4 2021 ➤  
Heating, air conditioning system - Edition 09.2021  
CAUTION  
Risk of frostbite from escaping pressurised refrigerant  
Risk of frostbite on skin and other parts of the body  
– Put on protective gloves.  
– Put on safety goggles.  
– Extract/drain refrigerant and then immediately open up re‐  
frigerant circuit.  
– Extract/drain refrigerant again if more than 10 minutes  
have passed since initial extraction and refrigerant circuit  
has not been opened up. Renewed evaporation has cre‐  
ated pressure in the refrigerant circuit.  
– Remove valve core -2- using socket -T10364/5-.  
Installing  
Installation is carried out in reverse order; note the following:  
– Perform function “Opening electrically actuated valves in re‐  
frigerant circuit for extracting, evacuating and charging” with  
⇒ Vehicle diagnostic tester ⇒ Rep. gr. 00; Starting diagnosis.  
– ⇒ Air conditioners with refrigerant R744 - General informa‐  
tion; Rep. gr. 87; Working with the air conditioner service  
station; Charging refrigerant circuit  
Tightening torques  
♦ ⇒ Rep. gr. 87; Exploded view - refrigerant lines  
3.18  
Removing and installing refrigerant  
pressure and temperature sender 2  
[G826]  
3.18.1  
Removing and installing refrigerant  
pressure and temperature sender 2  
[G826]  
Special tools and workshop equipment required  
♦ engine bung set -VAS 6122-  
38  
Rep. gr.87 - Air conditioning system  

Need help?

If after viewing the owner's manual or service manual you still have some unresolved questions about the car VW ID.4 you can write to us using the link below, describing your problem in detail, we try to answer all questions.


Ask your question on the page - Support!