Table of Contents > 4 Valve unit of heat pump > 4.4 Removing and installing refrigerant expansion valve 2 N637

VW ID.4 Heating & Air Conditioning System ➜ 4.4 Removing and installing refrigerant expansion valve 2 N637

ID.4 2021 ➤  
Heating, air conditioning system - Edition 09.2021  
Installing  
Install in reverse order of removal, observing the following:  
– Install seals and captive fasteners free of oil.  
When renewing expansion valve/shut-off valve:  
– Carry out function “Addressing routine for refrigerant valves”  
using ⇒ Vehicle diagnostic tester ⇒ Rep. gr. 00; Access to  
diagnoses.  
Tightening torques  
♦ ⇒ Rep. gr. 87; Assembly overview – valve unit of heat pump  
4.4  
Removing and installing refrigerant ex‐  
pansion valve 2 N637  
Special tools and workshop equipment required  
♦ ESD workplace -VAS 6613-  
Removing  
Refrigerant expansion valve 2 -N637- and refrigerant expansion  
valve 3 -N638- cannot be renewed separately.  
– Remove heat pump valve unit ⇒ Rep. gr. 87; Removing and  
installing heat pump valve unit.  
NOTICE  
Risk of damage to electrical components.  
Electrostatic discharge can cause damage to electrical com‐  
ponents.  
– Work on electrical components must always be performed  
on an ESD workplace.  
– Place heat pump valve unit on ESD workplace -VAS 6613-.  
– Remove bolts -1-, -2- and -3-.  
– Mark electrical connectors -2- to avoid interchange and un‐  
plug them.  
90  
Rep. gr.87 - Air conditioning system  
ID.4 2021 ➤  
Heating, air conditioning system - Edition 09.2021  
– Remove bolts -3-.  
– Detach refrigerant expansion valve 2 -N637- and refrigerant  
expansion valve 3 -N638- -1-.  
Installing  
Installation is carried out in reverse order; note the following:  
– Install seals and retaining elements, making sure they are  
free of oil.  
If expansion valves have been renewed:  
– Perform function “Addressing refrigerant valves” using ⇒ Ve‐  
hicle diagnostic tester ⇒ Rep. gr. 00; Starting diagnosis.  
Tightening torques  
♦ ⇒ Rep. gr. 87; Exploded view - heat pump valve unit  
4.5  
Removing and installing refrigerant ex‐  
pansion valve 3 N638  
Removing and installing  
Refrigerant expansion valve 3 -N638- is removed together with  
refrigerant expansion valve 2 -N637- and cannot be renewed  
separately ⇒ Rep. gr. 87; Removing and installing refrigerant  
expansion valve 2 N637.  
4.6  
Removing and installing refrigerant  
shut-off valve 1 N696  
Removing and installing  
Refrigerant shut-off valve 1 -N696- is removed together with  
refrigerant expansion valve 1 -N636- and cannot be renewed  
separately ⇒ Rep. gr. 87; Removing and installing refrigerant  
expansion valve 1 N636.  
4.7  
Removing and installing refrigerant  
shut-off valve 2 N640  
Special tools and workshop equipment required  
♦ ESD workplace -VAS 6613-  
♦ counterhold tool -T10630-  
Removing  
Refrigerant shut-off valve 2 -N640- and refrigerant shut-off valve  
3 -N641- cannot be renewed separately.  
– Remove heat pump valve unit ⇒ Rep. gr. 87; Removing and  
installing heat pump valve unit.  
4. Valve unit of heat pump  
91  

Need help?

If after viewing the owner's manual or service manual you still have some unresolved questions about the car VW ID.4 you can write to us using the link below, describing your problem in detail, we try to answer all questions.