Table of Contents > 3 Refrigerant circuit > 3.4 Assembly overview – refrigerant lines, R744

VW ID.4 Heating & Air Conditioning System ➜ 3.4 Assembly overview – refrigerant lines, R744

ID.4 2021 ➤  
Heating, air conditioning system - Edition 09.2021  
15 - Valve core  
❑ 2 Nm  
16 - Seal  
❑ Renew after removing  
17 - Refrigerant pressure and temperature sender -G395-  
❑ ⇒ Rep. gr. 87; Removing and installing refrigerant pressure and temperature sender G395  
❑ 10 Nm  
18 - Valve cap (low pressure)  
❑ 1 Nm  
19 - Evacuating and charging valve (low-pressure side)  
❑ ⇒ Rep. gr. 87; Removing and installing evacuating and charging valve (low-pressure and high-pres‐  
sure sides)  
❑ 1.5 Nm  
20 - Refrigerant line  
❑ ⇒ Rep. gr. 87; Removing and installing refrigerant line from heat exchanger for high-voltage battery to  
low-pressure line  
21 - Bolt  
❑ 2x  
❑ 20 Nm  
22 - Air conditioner compressor -VX81-  
❑ ⇒ Rep. gr. 87; Exploded view - air conditioner compressor  
❑ ⇒ Rep. gr. 87; Removing and installing air conditioner compressor VX81  
23 - Refrigerant line  
❑ ⇒ Rep. gr. 87; Removing and installing refrigerant line from condenser to air conditioner compressor  
VX81  
24 - Condenser  
❑ ⇒ Rep. gr. 87; Exploded view - condenser  
❑ ⇒ Rep. gr. 87; Removing and installing condenser  
25 - High-voltage battery heat exchanger  
❑ ⇒ Rep. gr. 87; Exploded view - heat exchanger for high-voltage battery  
❑ ⇒ Rep. gr. 87; Removing and installing heat exchanger for high-voltage battery  
3.4  
Assembly overview – refrigerant lines,  
R744  
3.4.1  
Exploded view - refrigerant lines  
3. Refrigerant circuit  
21  
ID.4 2021 ➤  
Heating, air conditioning system - Edition 09.2021  
1 - Bolt  
❑ Applies for all connec‐  
tions in illustration  
❑ Renew after removing  
❑ 13 Nm  
2 - Seal  
❑ Applies for all connec‐  
tions in illustration  
❑ Renew after removing  
3 - Retaining element  
❑ Applies for all connec‐  
tions in illustration  
❑ Renew after removing  
4 - Seal  
❑ Applies for all refriger‐  
ant pressure and tem‐  
perature senders in il‐  
lustration  
❑ Renew after removing  
5 - Dust ring  
❑ Applies for all refriger‐  
ant pressure and tem‐  
perature senders in il‐  
lustration  
❑ Renew after removing  
6 - Refrigerant pressure and  
temperature sender 2 -G826-  
❑ ⇒ Rep. gr. 87; Remov‐  
ing and installing re‐  
frigerant pressure and  
temperature sender 2  
G826  
❑ 40 Nm  
7 - Heat pump valve unit  
❑ ⇒ Rep. gr. 87; Exploded view - heat pump valve unit  
❑ ⇒ Rep. gr. 87; Removing and installing heat pump valve unit  
8 - Pressure limiting valve  
❑ Left-hand thread  
❑ Renew after removing  
⇒ a3.22.1 nd installing pressure limiting valve”, page 45  
❑ 14 Nm  
9 - Evacuating and charging valve  
❑ ⇒ Rep. gr. 87; Removing and installing evacuating and charging valve (low-pressure and high-pres‐  
sure sides)  
❑ 2 Nm  
10 - Valve cap  
11 - Refrigerant line  
❑ ⇒ Rep. gr. 87; Removing and installing refrigerant line between refrigerant shut-off valve 3 N641 and  
heat condenser  
12 - Refrigerant line  
22  
Rep. gr.87 - Air conditioning system  
ID.4 2021 ➤  
Heating, air conditioning system - Edition 09.2021  
❑ ⇒ Rep. gr. 87; Removing and installing refrigerant line between expansion valve N638/N637 and  
evaporator  
13 - Refrigerant pressure and temperature sender 4 -G828-  
❑ ⇒ Rep. gr. 87; Removing and installing refrigerant pressure and temperature sender 4 G828  
❑ 40 Nm  
14 - Refrigerant line  
❑ ⇒ Rep. gr. 87; Removing and installing refrigerant line between heat pump valve unit and evaporator  
15 - Refrigerant line  
❑ ⇒ Rep. gr. 87; Removing and installing refrigerant line between expansion valve N636/N696 and heat  
condenser  
16 - Refrigerant pressure and temperature sender -G395-  
❑ ⇒ Rep. gr. 87; Removing and installing refrigerant pressure and temperature sender G395  
❑ 40 Nm  
17 - Refrigerant line  
❑ ⇒ Rep. gr. 87; Removing and installing refrigerant line between air conditioner compressor VX81 and  
valve block N641/N640  
18 - Air conditioner compressor -VX81-  
❑ ⇒ Rep. gr. 87; Exploded view - air conditioner compressor  
❑ ⇒ Rep. gr. 87; Removing and installing air conditioner compressor VX81  
19 - Refrigerant line  
❑ ⇒ Rep. gr. 87; Removing and installing refrigerant line between gas cooler and refrigerant shut-off  
valve 2 N640  
20 - Refrigerant pressure and temperature sender 3 -G827-  
❑ ⇒ Rep. gr. 87; Removing and installing refrigerant pressure and temperature sender 3 G827  
❑ 40 Nm  
21 - Gas cooler  
❑ ⇒ Rep. gr. 87; Removing and installing gas cooler  
22 - Refrigerant line  
❑ ⇒ Rep. gr. 87; Removing and installing refrigerant line between dryer and gas cooler  
23 - Refrigerant line  
❑ ⇒ Rep. gr. 87; Removing and installing refrigerant line between air conditioner compressor VX81 and  
dryer  
24 - Refrigerant pressure and temperature sender 5 -G829-  
❑ ⇒ Rep. gr. 87; Removing and installing refrigerant pressure and temperature sender 5 G829  
❑ 40 Nm  
3.5  
Assembly overview – heat exchanger  
for high-voltage battery, R1234yf  
3.5.1  
Assembly overview - heat exchanger for high-voltage battery  
3. Refrigerant circuit  
23  

Need help?

If after viewing the owner's manual or service manual you still have some unresolved questions about the car VW ID.4 you can write to us using the link below, describing your problem in detail, we try to answer all questions.


Ask your question on the page - Support!